Sewage Treatment Plants
How it works
Raw sewage is gravitated into the two stage primary settlement zone. Here the solids settle out leaving the liquid to pass through into the irrigation zone where it is pumped to the distribution system on top of the media. The effluent is recycled through the media many times to achieve the necessary standard.
Finally, the fully treated effluent is pumped, or gravitated to the ditch, stream or soakaway.
Ten good reasons
-
Designed to BS 6297 - Design and installation of small sewage treatment works.
-
Single unit incorporating sample chamber, constructed of high quality Glass Fibre.
-
Ideal for the smaller home, or up to 12 workers.
-
Easily installed below ground level if required leaving only the inspection cover visible.
-
Unit produces high quality effluent 20:30 BOD:SS.
-
Optional Gravity or Pumped outlet.
-
Treated effluent can be discharged to a river or ditch or used for underground irrigation, subject to obtaining Consent to Discharge from the relevant authority.
-
Low maintenance costs, 12 monthly servicing and desludging.
-
3 year warranty on working parts.
-
Commissioning and Maintenance service available.
Treatment plants to serve a population range of 6 - 350 persons.

Download the technical specification to find out more or call:
CALL TODAY
01929 288013
For No Obligation Advice
24 hour call out
Other Systems We Install
The Marsh EnSign
The Marsh EnSign is certified to EN12566-3 and Designed in Accordance with British Water Loads & Flows Code of Practice.
|
|
![]() |
Marsh Industries Limited occupies a
unique position in the field of sewage and effluent treatment. They
have the technical expertise and experience gained from over 30
years in the UK Construction and manufacturing Industries.
Based in Northamptonshire, Marsh Industries are ideally placed to
deliver their product ranges across the U.K. They are committed
to offering the industry high specification product. They have recently
expanded their new U.K. assembly plant just outside Northampton
to cope with the increased demand on their products.
Our ENsign Uni: tank Sewage Treatment Plant range is testimony to
that commitment.
All ENsign Uni: tanks feature proven tested performance capabilities
certified to BSEN 12566-3. All components are manufactured to the
highest quality standards ISO 9001:2000.
Marsh supply products to major Sewage Treatment Contractors and
Consultants both here in the United Kingdom and throughout Europe.
Bio-Pure: Simple Solution Sewage Systems
The Bio-Pure sewage treatment range is designed to serve both domestic
and commercial properties that have no access to mains drainage.
The units are independently tested and certificated to BS EN 12566-3
in order to clean the final effluent to a standard of 20mg/l Biological
Oxygen Demand (BOD ) and 30mg/l Suspended Solids on a 95 percentile
basis.
The range caters for between 1 and 40 persons.
The unit offers a very discreet solution to on-site sewage treatment
as the small lid is flush with the ground and unlike its rivals,
the compressor housing is under the lid, with no visually intrusive
kiosk. The Bio-Pure itself is craftsman built, superb quality (using
thicker fibreglass than its rivals), very robust and carries a 25yr
guarantee on all GRP parts of the tank.
Why Use the Bio-Pure System?
· Affordable product with low running costs
· 25 years warranty on GRP and 2 year warranty on air pump
· Can be adapted to meet individual needs
· Visually unobtrusive lid with quiet air pump housed underneath
· The tank is odourless as solids are treated
· Typical 3-5 years emptying periods
· No requirement for concrete means easy installation and low costs
· No moving parts so that the unit will not fail
How does the Bio-Pure Work?
The Bio-Pure is a two-chamber unit and consists of a conical tank
that contains an inner tank aeration chamber, which is open at the
base. The space between the inner and outer tank is the clarifier
chamber. A draft tube, positioned 100mm from the base of the clarifier,
extends up into the aeration chamber.
Air from the compressor housed under the lid is piped to a diffuser
in the draft tube. Raw sewage enters the aeration chamber and air
surging up from the draft tube aerates the sewage, causing an aerobic
bacterial colony to establish and digest the organic matter. As
more raw sewage enters the chamber, an equal amount of effluent
displaces through the open bottom into the clarifier. The quiet
conditions in the clarifier allow all the suspended solids to sink
to the base of the clarifier. They are drawn back up the draft tube
by the upward flow of air, for further digestion in the aeration
chamber.
The clear effluent rises to the top of the clarifier and passes
over a weir into the outlet pipe. The Bio-Pure constantly recycles
the sewage via gravity and achieves nearly total solids digestion.
Most sewage treatment units consist of three chambers, the first
one being a Primary Settlement Tank, where the solids form a septic
sludge. They require regular emptying by tanker. Because the Bio-Pure
digests the solids as well as the organic matter in the liquid,
the unit has a much longer emptying interval than any three stage
unit. The interval is 3 to 5 years.
Bio-Pure Range
The Bio-Pure sewage treatment plant is available in 9 sizes to cater
for up to 40 persons. The Bio-Pure 1-5 are single units and the
Bio-Pure 6-9 are twin units.
In order to work out which plant is suitable for your property you
must abide by the British Water Code of Practice: Flows and Loads-2
Sizing Criteria, Treatment Capacity for Small Wastewater Treatment
Systems (Package Plants) (BW COP: 1/05).
A domestic dwelling is fairly straightforward to work out. This
is usually the number of bedrooms in the property plus two. For
example, a three bedroom house becomes five (requiring a Bio-Pure
2). However, if the treatment plant is required for more than one
property, then two must added to each dwelling. For example, a three
bedroom house plus two = five, a two bedroom house plus two = four
and a four bedroom house plus two = six, will become fifteen (5+4+6).
This will require a Bio-Pure 5.
For a non- residential property, the size Bio-Pure required will
depend on the purpose of the property. Please contact us and we
will be able to work out the correct size Bio-Pure required for
your needs (sizes 1 to 9).